Volume 22, Issue 2 (July 2015)                   J Birjand Univ Med Sci. 2015, 22(2): 94-103 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Arbabpour R, Ganji Fard M, Tabiee S, Saadatjoo S A. The Effect of Bi-Spectral Index on Recovery and Postoperative Complications in Patients Undergoing Caesarean section. J Birjand Univ Med Sci. 2015; 22 (2) :94-103
URL: http://journal.bums.ac.ir/article-1-1814-en.html
1- Faculty of Nursing and Midwifery, Birjand University of Medical Sciences, Birjand, Iran
2- Faculty of Medicine, Birjand University of Medical Sciences, Birjand, Iran
3- Department of Nursing and Member of Nursing-Midwifery Research Center, Birjand University of Medical Sciences, Birjand, Iran. , shahnaztabiee@bums.ac.ir
4- Department of Nursing, Faculty of Nursing and Midwifery, Birjand University of Medical Sciences, Birjand, Iran
Abstract:   (9461 Views)
Background and Aim: Anesthesia has several side effects which are different based on the type of surgery, medication, and depth of anesthesia. The present study aimed at identifying the effect of bi-spectral index monitoring on recovery and postoperative complications in caesarean. Materials and Methods: In this double-blinded clinical trial study with control group, 68 women who were candidates for caesarean were selected using available sampling method and were then randomly assigned in to two groups. For the control group, anesthetic maintenance drug was prescribed based on every body’s weight and hemodynamic conditions while intervention group received titrated dose of anesthetic maintenance drug as needed for maintaining bi-spectral index between 40 and 60. Data collection tool.included a researcher-designed checklist in which the time of extubation after surgery, discharge from the recovery unit (based on Aldert benchmark), and complications during recovery were recorded in addition to demographic data. The obtained data was analyzed by SPSSsoftware(V:16) using statistical independent T test, as well as Fisher Exact test. at the significant level of P<0.05. Results: Mean time of extubation was 7.76 ±3.12 in the control group and 3.59 ± 1.04 minutes in the intervention group (P<0.001). Mean time of discharge from recovery ward was 18.06 ± 5.92 in the control and 11.55 ±4.39 minutes in the intervention group (P<0.001). The incidence of postoperative recovery complications didn’t show any significant difference in the two groups (P>0.05). Conclusion: Bi-spectral indicator, as a monitoring of the depth of anesthesia in caesarean section, speeds up the extubation time, discharge from recovery, and mothers' consciousness to care their babies.
Full-Text [PDF 304 kb]   (3025 Downloads)    
Type of Study: Original Article | Subject: Anesthesiology
Received: 2015/02/10 | Accepted: 2015/07/11 | ePublished: 2015/08/10

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Journal of Birjand University of Medical Sciences

Designed & Developed by : Yektaweb